Intrasession Repeatability of Biometric Measurements Obtained with a Low-Coherence Interferometry System in Pseudophakic Eyes.


Por: Fukumitsu H, Camps VJ and Piñero DP

Publicada: 1 feb 2020 Ahead of Print: 28 ago 2019
Resumen:
Purpose: To evaluate the intrasession repeatability of the biometric measurements obtained with a low-coherence reflectometry optical biometer in pseudophakic eyes implanted with two different types of intraocular lens (IOL).Methods: Prospective, single-center, comparative study including 69 eyes of 69 patients with ages ranging from 51 to 92 years. Previous uncomplicated cataract surgery had been performed in all patients 1 to 2 months before measurements, with implantation of the Acrysof SN60WF IOL in 35 eyes (35 patients, group 1) and the IOL Akreos MI60 in 34 eyes (34 patients, group 2). A complete postoperative ophthalmological examination was performed including three consecutive measurements with the "Aladdin" system from (Topcon, Japan). Intrasession repeatability of axial length (AXL), anterior chamber depth (ACD) and IOL thickness (IOLT) were assessed with the within-subject standard deviation (S(w)), intraobserver precision (1.96 × S(w)), coefficient of variation (CV) and intraclass correlation coefficient (ICC). Results: The S(w) for AXL measurements was 0.03 and 0.05 mm in groups 1 and 2, respectively, with ICC of 1.000 and 0.999 (CV: 0.14% and 0.22%) (p = 0.031). Concerning pseudophakic ACD, the S(w) was 0.03 and 0.09 mm in groups 1 and 2, respectively, with ICC of 0.992 and 0.956 (CV: 0.55% and 1.75%) (p = 0.021). The variability of IOLT measurements was high in both groups, with S(w) of 0.12 and 0.29 mm for groups 1 and 2 (p = .008), respectively, and ICC of 0.065 and 0.770 (CV: 20.84% and 62.39%).Conclusions: The optical biometer "Aladdin" (Topcon, Japan) provides consistent measurements of AXL and ACD in pseudophakic eyes. However, there is a limitation in the consistency of IOLT measurements that should be investigated further.

Filiaciones:
:
 Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain

 Department of Ophthalmology, Marina Baixa Hospital, Alicante, Spain

 Department of Ophthalmology, Vithas Medimar International Hospital, Alicante, Spain

Camps VJ:
 Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain

:
 Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain

 Department of Ophthalmology, Vithas Medimar International Hospital, Alicante, Spain
ISSN: 14602202





Current Eye Research
Editorial
Taylor and Francis Ltd., England, Reino Unido
Tipo de documento: Article
Volumen: 45 Número: 2
Páginas: 221-226
WOS Id: 000483833400001
ID de PubMed: 31438734

MÉTRICAS