Corneal Biomechanical Parameters With Corneoscleral Contact Lenses in Post-Laser In Situ Keratomileusis Eyes


Por: Montalt JC, Porcar E, Espana-Gregori E and Peris-Martinez C

Publicada: 1 nov 2018 Ahead of Print: 21 sep 2017
Resumen:
Objective: To evaluate corneal biomechanical parameters wearing corneoscleral contact lenses (CScL) in patients with irregular corneas after laser in situ keratomileusis (LASIK). Methods: Data from patients fitted with CScL because of corneal surface irregularities after complicated LASIK surgery were selected by two eye clinics. Previously and after 1 year of CScL fitting, corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated intraocular pressure (IOPcc), and central corneal thickness were evaluated. In addition, visual acuity, subjective comfort, and wearing time CScL were reported. Results: The study comprised 27 eyes. Statistically significant differences were found in visual acuity between the best spectacle-corrected vision and after CScL fitting [mean +/- SD, 0.16 +/- 0.03 logarithm of the minimum angle of resolution (logMAR) and 0.01 +/- 0.06 logMAR, respectively; P<0.001]. In addition, the patients reported high subjective comfort ratings (22 eyes were comfortable or very comfortable) and prolonged usage times (mean +/- SD, 12.67 +/- 1.98 hr of continuous wear a day). Statistically significant differences were found in the CRF between before CScL fitting and after 1 year of CScL wear (mean +/- SD, 7.57 +/- 0.87 and 7.68 +/- 0.84 mm Hg, respectively; P=0.015). Central corneal thickness, CH, and IOPcc showed slight differences after 1 year of CScL wear (1.78 mu m, 0.04 and 0.21 mm Hg, respectively). Conclusion: Corneal biomechanical parameters increased slightly, although significantly for CRF, apparently without adverse clinical effects in post-LASIK eyes with irregular corneas after wearing CScL for 1 year.

Filiaciones:
Montalt JC:
 Department of Optics, Optometry and Vision Sciences (J.C.M., E.P.), Physics College, University of Valencia, Burjassot, Valencia, Spain

 Department of Surgery (E.E.), Ophthalmology Unit, la Fe University and Polytechnic Hospital, Faculty of Medicine and Odontology, University of Valencia, Hospital la Fe, Valencia, Spain

 and FISABIO Oftalmologia Medica (C.P.), Cornea Unit and Anterior Segment Diseases, Catholic University of Valencia, Valencia, Spain
ISSN: 15422321





EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE
Editorial
LIPPINCOTT WILLIAMS & WILKINS, United States, Estados Unidos America
Tipo de documento: Article
Volumen: 44 Número:
Páginas: 65-69
WOS Id: 000457840400012
ID de PubMed: 28945645

MÉTRICAS